TECHNICAL NOTES |
|
|
|
Year : 2020 |
Volume
: 30 | Issue : 3 | Page
: 376-378 |
|
Retrieval of retained pigtail in the liver
Manthreshwar Premkumar, George K Chiramel, Shyamkumar N Keshava
Department of Radiology, Christian Medical College, Vellore, Tamil Nadu, India
Correspondence Address:
Dr. Shyamkumar N Keshava Department of Radiology, Christian Medical College, Ida Scudder Road, Vellore - 632 004, Tamil Nadu India
 Source of Support: None, Conflict of Interest: None  | Check |
DOI: 10.4103/ijri.IJRI_97_20
|
|
The incidence of catheter breakage during percutaneous image-guided treatment of liver hydatid is very rare. A “telescoping” technique was used to retrieve the broken pigtail in this case report. Alternative options for pigtail retrieval are briefly discussed.
|
|
|
|
[FULL TEXT] [PDF]* |
|
 |
|