Artifacts in cranial MRI caused by extracranial foreign bodies and analysis of these foreign bodies


1 Department of Neurosurgery, Erzincan University, Erzincan, Turkey
2 Department of Chemistry, Faculty of Arts and Sciences, Sinop University, Rize, Turkey
3 Department of Radiology, Dışkapı Training and Research Hospital, Ankara, Turkey
4 Department of Radiology, Faculty of Medicine, Recep Tayyip Erdogan University, Rize, Turkey
5 Department of Neurosurgery, Faculty of Medicine, Recep Tayyip Erdogan University, Rize, Turkey
6 Department of Physics, Faculty of Arts and Sciences, Recep Tayyip Erdogan University, Rize, Turkey
7 Department of Biostatistics, Faculty of Medicine, Erzincan University, Erzincan, Turkey

Correspondence Address:
Dr. Selim Kayaci
Department of Neurosurgery, Faculty of Medicine, Erzincan University, Rize
Turkey
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/ijri.IJRI_211_18

Rights and Permissions

Purpose: The purpose of our study was to conduct a chemical analysis of extracranial foreign bodies (FBs) causing artifacts in cranial magnetic resonance imaging (MRI) and to investigate the association between chemical composition, magnetic susceptibility, and artifact size. Materials and Methods: A total of 12 patients were included in the study. The FBs responsible for the artifacts were visualized using cranial computed tomography (CT). Artifact-causing FBs were removed from the scalps of 10 patients and analyzed using scanning electron microscope with energy dispersive spectroscopy (SEM-EDS), X-ray diffraction spectroscopy (X-RD), and Fourier-transform infrared spectroscopy (FT-IR). The magnetic susceptibility of the samples was determined using the reference standard material MnCl2.6H2O. The volume of the MRI artifacts was measured in cubic centimeters (cm3). Results: EDS results demonstrated that the mean Fe ratio was 5.82% in the stone samples and 0.08% in the glass samples. Although no phase peaks were detected in the X-RD spectra of the glass samples, peaks of Fe2O3, Al2Ca (SiO4) were detected in the X-RD spectra of the stone samples. The FT-IR spectra revealed metal oxide peaks corresponding to Fe, Al, in the stone samples and peaks confirming Al2SiO5and Na2SiO3structures in the glass samples. The mean volumes of the MRI artifacts produced by the stone and glass samples were 5.9 cm3 and 2.5 cm3, respectively. Conclusions: Artifacts caused by extracranial FBs containing metal/metal oxide components are directly associated with their chemical composition and the artifact size are also related to element composition and magnetic susceptibility.


[FULL TEXT] [PDF]*
Print this article     Email this article

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
  Citation Manager
 Access Statistics
  Reader Comments
  Email Alert *
  Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed66    
    Printed1    
    Emailed0    
    PDF Downloaded34    
    Comments [Add]    

Recommend this journal