Sir,

We would like to thank the author for the review and showing great interest in our article. We would also like to thank them for the observations that they have made as well as for clarifications.

Few cases of schwannoma were encountered by us. These had cystic/necrotic changes. MR spectroscopy revealed lipid/lactate peak elevation with significant decrease in choline integral values. However, more cases need to be evaluated related to the significance of these findings.

We concur with the views expressed regarding previous few studies, where the results have been expressed in terms of metabolite ratios.[1] However, pertaining to our study, where most of the lesions were diffused and histopathological confirmation was available for cases, the comparison was made in relation to integral values of the metabolites and deviation from normal spectra, and metabolite ratios were not used.

Financial support and sponsorship

Nil.

Conflicts of interest

There are no conflicts of interest.



 
   References Top

1.
Hock A, Henning A, Boesiger P, Kollias SS. 1H-MR spectroscopy in the human spinal cord. Am J Neuroradiol 2013;34:1682-9.  Back to cited text no. 1
    

Top
Correspondence Address:
Babu Peter Sathyanathan
Barnard Institute of Radiology, Madras Medical College, Chennai, Tamil Nadu
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/ijri.IJRI_417_18

Rights and Permissions




 

Top
 
 
  Search
 
   Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
    Email Alert *
    Add to My List *
* Registration required (free)  


    References

 Article Access Statistics
    Viewed326    
    Printed2    
    Emailed0    
    PDF Downloaded29    
    Comments [Add]    

Recommend this journal