Indian Journal of Radiology Indian Journal of Radiology  

   Login   | Users online: 456

Home Bookmark this page Print this page Email this page Small font sizeDefault font size Increase font size     

 

MISCELLANEOUS Table of Contents   
Year : 2018  |  Volume : 28  |  Issue : 2  |  Page : 258-262
A simple quality control tool for assessing integrity of lead equivalent aprons


Department of Radiology, Christian Medical College and Hospital, Vellore, Tamil Nadu, India

Correspondence Address:
Dr. Roshan S Livingstone
Department of Radiology, Christian Medical College and Hospital, Vellore - 632 004, Tamil Nadu
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/ijri.IJRI_374_17

Rights and Permissions

Background: Protective lead or lead-equivalent (Pbeq) aprons play a key role in providing necessary shielding from secondary radiation to occupational workers. Knowledge on the integrity of these shielding apparels during purchase is necessary to maintain adequate radiation safety. Aim: The aim of the study was to evaluate the lead equivalence in aprons based on simple quality assessment tool. Materials and Methods: 0.25 mm and 0.5 mm lead and lead-free aprons from 6 manufacturers were assessed using a calibrated digital X-ray unit. The percentage attenuation values of the aprons were determined at 100 kVp using an ionization chamber and the pixel intensities were analyzed using digital radiographic images of lead apron, copper step wedge tool, and 2 mm thick lead. Results: Mean radiation attenuation of 90% and 97% was achieved in 0.25 mm and 0.5 mm lead or lead-free aprons respectively. The pixel intensities from 0.25 mm Pbeq apron correspond to 0.8–1.2 mm thickness of Cu while 0.5 mm Pbeq aprons correspond to 2.0–2.8 mm of Cu. Conclusion: Pixel intensity increased with increase in the thickness of copper step wedge indicating a corresponding increase in lead equivalence in aprons. It is suggestive that aprons should be screened for its integrity from the time of purchase using computed tomography (CT), fluoroscopy, or radiography. It is recommended that this simple test tool could be used for checking lead equivalence if any variation in contrast is seen in the image during screening.


[PDF]*
Print this article     Email this article

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
  Citation Manager
 Access Statistics
  Reader Comments
  Email Alert *
  Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed1035    
    Printed30    
    Emailed0    
    PDF Downloaded121    
    Comments [Add]    

Recommend this journal