Indian Journal of Radiology Indian Journal of Radiology  

   Login   | Users online: 1599

Home Bookmark this page Print this page Email this page Small font sizeDefault font size Increase font size     

 

GASTROINTESTINAL RADIOLOGY AND HEPATOLOGY Table of Contents   
Year : 2017  |  Volume : 27  |  Issue : 2  |  Page : 161-166
MR fistulography with percutaneous instillation of aqueous jelly: A cost effective technique innovation


1 Department of Radiodiagnosis, Command Hospital Air Force, Bengaluru, Karnataka, India
2 Department of Radiodiagnosis, Indian Naval Hospital Ship, Mumbai, India
3 Department of Radiodiagnosis, JJM Medical College, Davangere, Karnataka, India

Correspondence Address:
Rohit Aggarwal
Department of Radiodiagnosis, Command Hospital Air Force, Bengaluru - 560 007, Karnataka
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/ijri.IJRI_373_16

Rights and Permissions

Background: Perianal fistula is a commonly encountered condition in routine surgical practice. Accurate presurgical mapping of these tracts is vital to prevent recurrence. We have assessed the effectiveness of percutaneous instillation of aqueous jelly prior to magnetic resonance (MR) fistulography. Aims and Objectives: To study the role of percutaneous instillation of aqueous jelly in fistulous tracts prior to MR fistulography. Materials and Methods: All patients with active discharge, referred for MR fistulography between January 2014 and April 2016, were included in this study. Approximately 3–5 ml of sterile aqueous jelly was percutaneously instilled into the external openings prior to MR fistulography. Post MR fistulography, patients were monitored till surgery for pain, fever, or bleeding.The type of fistulae, location of internal openings, lateral ramifications, and presence of abscess were compared with per operative findings for diagnostic accuracy. Results: Sixty-four patients enrolled in our study had undergone preoperative MR fistulography with aqueous jelly instillation. MR fistulography revealed a total of 77 tracts and showed a sensitivity and specificity of 100% in delineation of type of tract. Forty-nine internal openings were identified with 94.2% sensitivity, 100% specificity, and 95.3% accuracy. 90.5% sensitivity, 100% specificity, and accuracy of 97% were observed in delineation of lateral ramifications. None of the patients reported pain, fever, or bleeding post procedure till surgery. Conclusion: Percutaneous instillation of aqueous jelly prior to MR fistulography is a safe, cost effective, and accurate technique to provide a comprehensive delineation of the complex anatomy of perianal fistulae.


[FULL TEXT] [PDF]*
Print this article     Email this article

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
  Citation Manager
 Access Statistics
  Reader Comments
  Email Alert *
  Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed4324    
    Printed40    
    Emailed0    
    PDF Downloaded370    
    Comments [Add]    

Recommend this journal