   Abstract 

The incidence of end-stage renal disease is significantly increasing and most patients who require renal transplantation are undergoing hemodialysis through tunneled/non-tunneled dialysis catheters and arteriovenous fistulas. The greatest disadvantage of the hemodialysis access is  the limited durability of the arteriovenous fistulas and grafts, which, on average, remain patent for <3 years, but are the lifeline for hemodialysis patients. Catheter-directed interventions are successful in re-establishing flow in more than 80% of thrombosed hemodialysis fistulas and have become the treatment of choice for failing or thrombosed accesses. However, these interventions are expensive and require a tertiary center with well-equipped labs. The novel technique of needle-directed thrombolysis is less expensive and can be done on an OPD basis in any primary healthcare setup. To the extent we have searched, no such technique has been published so far in the English literature.

Keywords: Hemodialysis fistula; thrombolysis; USG-guided procedure

How to cite this article:
Vikrama KA, Srivalli N, Venkataramana RS. USG-guided needle-directed pulse-spray pharmaco-mechanical thrombolysis of hemodialysis grafts/fistula: A novel technique. Indian J Radiol Imaging 2015;25:244-5

How to cite this URL:
Vikrama KA, Srivalli N, Venkataramana RS. USG-guided needle-directed pulse-spray pharmaco-mechanical thrombolysis of hemodialysis grafts/fistula: A novel technique. Indian J Radiol Imaging [serial online] 2015 [cited 2019 Jul 19];25:244-5. Available from: http://www.ijri.org/text.asp?2015/25/3/244/161442

   Introduction Top


Percutaneous thrombolysis of hemodialysis fistulas became a well-established and promising technique after the development of the pharmaco-mechanical technique of pulse-spray thrombolysis. [1],[2] All these years, the catheter-directed interventions have been widely used for thrombolysis. They require patient admission, preliminary investigations, and fluoroscopic guidance. Thrombolysis is done using infusion catheters placed inside the grafts/thrombosed vein, followed by balloon angioplasty or stenting if required. This new technique of needle-directed thrombolysis can be done as an OPD procedure/bedside with USG guidance. It does not require the use of fluoroscopy or the infusion catheters and wires, thereby significantly reducing the cost of the procedure and hospital stay.


   Procedure Top


After the initial USG examination (GE Logiq e, USA) of the thrombosed segment, 5000 units of heparin was injected intravenously. Under aseptic precautions and USG guidance, multiple 26 G needles were inserted into the thrombosed vein or graft and were connected to three-way stop cocks with short connectors [Figure 1]. The thrombolytic solution was prepared by dissolving 2.5 lakh units of Urokinase (U Frag, Bharat serum and vaccines Ltd, India) in 10 ml of heparinized saline (1000 U heparin) as described by Valji et al. [3] Manual pulse injections of 0.2-0.3 ml aliquots were applied to each needle about every 30 s with a 1 ml syringe. Forceful and rapid injections were essential to adequately penetrate the thrombus and to achieve uniform thrombolysis. Care was taken to keep air bubbles out of the system. Intermittent USG screening was done to assess the progress of the thrombolysis [Figure 2] and [Figure 3]. If the flow was not restored at the end of the injections, another 2.5 L Urokinase was prepared and used. After recanalization, low-molecular-weight (LMW) heparin was administered for the next 2-3 days to prevent re-thrombosis due to the residual clot burden and also to manage the small risk of pulmonary embolism. The arteriovenous (AV) fistula/graft was ready to be used for dialysis almost on the same day.
Figure 1: Photograph showing multiple 26 G needles inserted into the arteriovenous fistula (AVF) graft in the arm. Three-way stop cocks with connectors are connected to the needles

Click here to view
Figure 2: Doppler image showing hypoechoic thrombus (horizontal arrow) within the AVF graft (vertical arrows). No colour flow seen within the graft

Click here to view
Figure 3: Post procedure doppler showing restored flow (horizontal arrow) within the arteriovenous fistula graft with few residual clots (vertical arrow) in the periphery

Click here to view



   Conclusion Top


USG-guided needle-directed thrombolysis of AV fistula/grafts is a promising alternative to the catheter-directed thrombolysis. It can be done as an OPD procedure. A proper study is required to prove its safety and cost-effectiveness.

 
   References Top

1.
Cooper SG. Original report. Pulse-spray thrombolysis of thrombosed hemodialysis grafts with tissue plasminogen activator. AJR Am J Roentgenol 2003;180:1063-6.  Back to cited text no. 1
    
2.
Bookstein JJ, Fellmeth B, Roberts A, Valji K, Davis G, Machado T. Pulsed-spray pharmacomechanical thrombolysis: Preliminary clinical results. AJR Am J Roentgenol 1989;152:1097-100.  Back to cited text no. 2
    
3.
Valji K, Bookstein JJ, Roberts AC, Oglevie SB, Pittman C, O′Neill MP. Pulse-spray pharmacomechanical thrombolysis of thrombosed hemodialysis access grafts: Long-term experience and comparison of original and current techniques. AJR Am J Roentgenol 1995;164:1495-503.  Back to cited text no. 3
    

Top
Correspondence Address:
Dr. KS Amitha Vikrama
Sakra World Hospital, 52/2 and 52/3, Devarabeesanahalli, Varthur Hobli, Bangalore - 560 103, Karnataka
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/0971-3026.161442

Rights and Permissions


    Figures

  [Figure 1], [Figure 2], [Figure 3]



 

Top
 
 
  Search
 
   Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
    Email Alert *
    Add to My List *
* Registration required (free)  


    Abstract
   Introduction
   Procedure
   Conclusion
    References
    Article Figures

 Article Access Statistics
    Viewed1953    
    Printed19    
    Emailed0    
    PDF Downloaded175    
    Comments [Add]    

Recommend this journal