Recent advances in intestinal imaging


Department of Clinical Radiology, South Warwickshire NHS Foundation Trust, Warwick, England, United Kingdom

Click here for correspondence address and email

Date of Web Publication24-Sep-2011
 

   Abstract 

In recent years, advances in scanner technology and competition from other specialties have produced rapid changes in the way the intestines are imaged. MRI and CT scan along with the traditional enteroclysis examination have emerged at the forefront of intestinal imaging. Functional modalities such as diffusion and perfusion imaging are also changing the way tumors and inflammatory bowel diseases are evaluated. CT colonography is now a valid alterative to optical colonoscopy. Contrast-enhanced USG is being used for the assessment of inflammation and post-treatment changes. In this review, recent advances in intestinal imaging are described.

Keywords: Computed tomography; intestines; magnetic resonance imaging

How to cite this article:
Sinha R. Recent advances in intestinal imaging. Indian J Radiol Imaging 2011;21:170-5

How to cite this URL:
Sinha R. Recent advances in intestinal imaging. Indian J Radiol Imaging [serial online] 2011 [cited 2019 Sep 18];21:170-5. Available from: http://www.ijri.org/text.asp?2011/21/3/170/85363

   Introduction Top


Traditionally, barium examinations have been the mainstay of radiological investigations of the small and large intestines. However, the standard barium follow-through (SBFT) examination has high false-negative and false-positive rates for the detection of abnormalities. [1] This is because only 25-35% of the bowel length can be adequately assessed on a standard examination due to overlapping loops, poor coating, and other factors. [1] Several new techniques have therefore evolved that provide better diagnostic capabilities and higher accuracy rates. [2],[3],[4] In this article, the newer techniques and modalities being employed for imaging of the bowel are detailed, with an overview of their strengths and weaknesses.


   Current Role of Barium Examinations Top


Innovations in intestinal imaging have been driven by the demand for detailed clinical information and the limitations of standard methods of small-bowel examination. Alternative techniques such as the pill camera that allow high-definition color views of the bowel have appeared. At an average frequency of two frames per second, a total of >50,000 frames are collected in 7-8 h as the pill camera travels through the bowel. Despite the high-resolution images provided by this technique, it has become increasingly apparent that not all mucosal abnormalities seen on wireless capsule endoscopy are clinically relevant. Mucosal erosions may be seen in as many as 14% of asymptomatic healthy subjects, with the rate of such abnormalities being more than double this in users of nonsteroidal anti-inflammatory drug (NSAID) agents. [5] Furthermore, the pill camera does not provide any information about mural and extramural abnormalities. Therefore, the need for a complementary radiologic examination is apparent. Contraindications to the pill camera include bowel obstruction, history of bowel strictures or fistulae.

The most accurate conventional radiologic method in the diagnosis of small-bowel obstruction, inflammatory bowel disease (IBD), gastrointestinal bleeding, and neoplasms is double-contrast enteroclysis. [2] However, SBFT has remained the most commonly performed method for the investigation of small-bowel diseases because of its ease of performance and the relative technical complexity of enteroclysis as well as the discomfort to patients during intubation. The SBFT has a low diagnostic yield and low negative predictive value. In a recent study, 8% of patients with known Crohn disease encountered capsule retention despite a previous normal SBFT. Non-intubation examinations do not fully distend the bowel, and therefore partial strictures, obstructions, and small polyps or masses can be easily missed. The advantage of enteroclysis examinations is that there is optimal bowel distension, which allows detailed evaluation of all segments [6] [Figure 1].
Figure 1: Barium-methylcellulose bowel examination shows linear filling defects (webs) (arrows) in the distal ileum secondary to the use of nonsteroidal anti-inflammatory drugs (NSAIDs)

Click here to view


Enteroclysis examination with barium-methylcellulose is the most commonly performed enteroclysis method in many countries. However, the disadvantage with this technique is that methylcellulose has a washout effect on superficial mucosal features. Subtle surface abnormalities get effaced as more methylcellulose is infused to achieve a good double-contrast effect and bowel distension. Therefore, this method should be reserved for detection of obstruction or mass lesions or it should be used in combination with CT scan or MRI exams. [2],[3],[4],[7] Fluoroscopic evaluation with positive enteral contrast can help distinguish fixed (stenotic) segments of small-bowel narrowing from spasm caused by active inflammation in patients who have Crohn disease and can also differentiate mild stenosis from normal peristaltic contractions.

On the other hand, double-contrast enteroclysis with air/CO 2 and barium is by far the best method for showing mucosal details of the small bowel. [5],[7],[8] A scientific study comparing double-contrast air enteroclysis with histopathology showed good correlation between the two for the visualization of aphthae and small ulcers [Figure 2].
Figure 2: Magnified view from an air-barium double contrast enteroclysis examination shows early linear mucosal breaks and ulcers (arrow) in a patient with proven Crohn disease

Click here to view


Therefore, if capsule endoscopy is unavailable or contraindicated, double-contrast air enteroclysis should be the preferred modality for the detection of early ulcerations, irregularities, and erosions of the small bowel. This technique should also be employed if other imaging tests have been negative and a suspicion of small-bowel pathology still persists. Double-contrast methylcellulose-barium enteroclysis is the best method for the detection of strictures and partial stenoses. [1],[5] This technique can be performed on its own or it can be combined with CT scan or MRI. The pill camera remains the most sensitive method for the evaluation of gastrointestinal tract bleeding. [8],[9]


   CT Scan and MRI Top


Bowel opacification

The most important factor for obtaining good intestinal imaging is optimal distension of the bowel with enteral contrast. Enteral contrast can be positive, neutral, or negative, depending on its density (HU). Positive enteral contrast agents range from a 4-15% contrast solution to a dilute 0.3-6% barium solution. The author prefers an 8-10% iodine concentration of water-soluble contrast because this density allows diagnostic fluoroscopic observations as well as diagnostic radiographs. Neutral contrast agents can be methylcellulose, mannitol, polyethyl glycol, or other bulk fibers and have a density similar to water (0 HU). Negative contrast is mainly used in the imaging of the colon [CT colonography (CTC)], where CO 2 or air is insufflated per rectum.

Enteral contrast can be administered via the intubation method (CT enteroclysis/MRI enteroclysis) or the enterographic method [Figure 3]. [6] For enterographic examination, the patient ingests a large volume of contrast over a set period of time prior to imaging. The author prefers to use 1300 ml of contrast ingested over 50 min. The 1300 ml is divided into two aliquots: the first lot is ingested with a prokinetic agent (metoclopromide) over 25 min and the second lot is consumed over the next 25 min. Just prior to the scan, 200 ml of contrast is administered to outline the stomach and duodenum. The main advantage of the enterographic examination is that it is more acceptable to patients than enteroclysis as intubation may be an unpleasant experience for patients. [10] The disadvantage of enterograpic examination is that it may not provide uniform or adequate bowel distension as compared to enteroclysis.
Figure 3: Axial CT enteroclysis examination demonstrates a segment of kinked bowel (arrowhead) and several adhesive bands across other segments (arrows). This patient had undergone several negative CT examinations previously

Click here to view


Water is also routinely used as a neutral enteral contrast agent at many centers; however, its use in dedicated small-bowel studies should be discontinued. Water has been found to provide inadequate distension (at various volumes and ingestion times) of the small bowel in many studies. [10],[11] This is because water undergoes rapid reabsorption in the bowel and fails to adequately distend the distal small-bowel segments. Therefore, additives (such as contrast, mannitol or other agents) need to be mixed with water to provide an iso-osmolar solution that does not get reabsorbed and remains in the lumen to provide distension. The use of water as a contrast agent may lead to false-negative examinations. Furthermore, collapsed loops are known to demonstrate hyperenhancement on post-contrast studies and this may lead to false-positive diagnoses. Therefore, the author strongly discourages the use of water as an enteral agent in dedicated studies of the small bowel. The only instance where water may be used as an enteral agent is in the enteroclysis technique where the operator exclusively controls distension of the bowel and rate of infusion.

CT scan

The advantage of current-generation multidetector CT (MDCT) scanners is increased anatomical coverage with thinner sections, which provide high-quality mutiplanar (MPR) images and fewer motion artifacts. [12],[13] Positive-contrast CT enteroclysis (CTE) or enterography (CTEG) may be used mainly for the diagnostic workup of small-bowel obstruction or in suspected cases of small intestinal tumors or metastases. One of the drawbacks of positive contrast is the production of streak artifacts on MPR reconstruction, particularly on older CT scanners that cannot produce isotropic voxels (slice thickness >2 mm).

Further refinements to these techniques include the use of neutral contrast. The advantages of neutral contrast are that it does not obscure the mucosal lining and does not produce streak artifacts. (It must be remembered that fluoroscopy is not possible with neutral contrast). Neutral contrast allows better visualization of mucosal enhancement, ulcers, and bleeds. Therefore, neutral-contrast CTE or CTEG is indicated for the workup of patients with inflammatory bowel bleed, gastrointestinal bleeding, and suspected bowel pathologies. [6]

CTC is a technique where the colon is imaged noninvasively. Several studies have shown that CTC has high sensitivity and specificity (>95%) for the detection of polyps and cancers [14] [Figure 4]A. The colon is distended by insufflating air/CO 2 per rectum. [15] Datasets of the distended colon are obtained, which can then by manipulated by software to provide virtual colonoscopy images. Recent advances include automated polyp detection software and virtual dissection views of the colon. Translucency rendering software allows differentiation between fecal matter and polyps [Figure 4]B.
Figure 4 (A,B): Screenshot (A) from a CT colonographic examination shows a polyp in the colon. Top two axial images show the location of the polyp within a marker box, whereas the bottom two are virtual 3D images in the supine and prone positions which detail polyp size and distance from the rectum. Mucosal views (B) show a virtual dissection view of the colon with a small polyp (arrow) in the left image. On the right, translucency rendering shows this lesion to be homogenously dense (red), implying this is retained fecal matter

Click here to view


MRI

MRI is an emerging technique for comprehensive and functional bowel imaging. [16] The absence of ionizing radiation and high-contrast resolution are the major advantages of MRI over CT scan. The nonionizing aspect of MRI makes it particularly suited for use in patients with IBD who may need repeated imaging. The inherent high-contrast resolution can provide high diagnostic confidence and also facilitate the detection of discriminating features of intestinal diseases. [17]

T 1 W and T 2 W imaging sequences for the imaging of the bowel have been reported in earlier studies. [10],[17],[18] However, in recent years, advances with ultra-fast sequences based on steady-state precession have revolutionized bowel imaging. These sequences can be performed within a single breath-hold, and when combined with bowel paralysis (using antiperistaltic agents, e.g., buscopan), the technique allows rapid imaging of the small bowel. These sequences are called true fast imaging with steady-state precession (true-FISP), balanced fast field-echo (FFE), or fast imaging employing steady-state acquisition (FIESTA). [14] These sequences are relatively insensitive to motion artifacts and provide high contrast between the bowel wall, lumen, and the mesentery. The problem with these sequences is the presence of a "black boundary" artifact along the bowel wall, which may mask small lesions or abnormalities. The addition of fat suppression may help in reducing the effects of the black boundary artifact [Figure 5]. Fast sequences also obviate the need for long breath-holds, and thus reduce motion or respiratory artifacts.
Figure 5: A patient with Crohn disease. MRI enterography examination shows good opacification of the small and large bowel with thickening of the inflamed cecal wall (arrow)

Click here to view


T 2 W fast sequences based on rapid acquisition and relaxation, such as half-Fourier single-shot turbo spin-echo (HASTE) or single-shot fast spin-echo (SSFSE) sequences, are also used and can provide high contrast between the lumen and the bowel wall, producing images akin to a conventional barium study. These sequences are susceptible to motion artifacts produced by flow voids and peristalsis. T 1 W sequences in two or three dimensions are used for post-contrast imaging. Fat saturation can be used to increase contrast resolution and also for better assessment of bowel enhancement.

Parallel imaging techniques can help in improving spatial and temporal resolution on MRI. It is possible that with this technique, high-resolution three-dimensional datasets comprising isotropic voxels of the entire abdomen could be produced within a single breath-hold. Three-dimensional datasets allow high-quality MPR reconstructions, which can increase diagnostic confidence.

USG

The main advantages of USG are its nonionizing character and general availability. The dynamic, real-time qualities of USG provide high temporal resolution. [19] USG also allows observation of normal or abnormal bowel peristalsis, fixity, and compressibility. Some studies have employed bowel distension using oral contrast (hydrosonography) although its use remains limited. [20] The current-generation high-frequency probes provide greater spatial resolution than CT scan or MRI [Figure 6]. Contrast-enhanced USG can provide detailed information about vascularity and inflammation of the bowel. [21]
Figure 6: High-resolution USG image shows an inflamed bowel segment, with marked enhancement of the mucosal vessels (arrowheads) and engorgement of the penetrating blood vessels (arrow)

Click here to view



   Functional Imaging Top


Several new techniques are now available that can provide functional information in bowel pathologies.

MRI fluoroscopy: Changes in bowel kinetics can be evaluated on MRI fluoroscopy to demonstrate either an obstructive element or abnormalities in peristalsis. MRI fluoroscopy can provide functional information regarding bowel motility and may help distinguish between fibrotic strictures and functional bowel spasm. [10]

PET/CT: Positron emission tomography (PET)/CT depends on the uptake of tracer by abnormal or highly metabolic tissue. Typically, cancers or metastases show up as hot spots due to their higher metabolic rate as compared to the surrounding tissues. The role of PET/CT in intestinal imaging is mainly related to cancer imaging and the detection of distant metastases. [22] PET-CT also has a role is the detection of recurrent cancers and in quantifying malignancy in suspicious nodes [Figure 7]. [23],[24]
Figure 7: PET/CT image shows a recurrent rectal tumor as a hot spot (arrow) just anterior to the presacral fascia

Click here to view


Diffusion-weighted MRI imaging:0 Diffusion-weighted MRI signal is derived from the motion of water molecules within cells or extracellular spaces.[25] Highly cellular tumors have restricted water diffusion and show up as areas retaining high signal intensity on high b value (800-1000 s/mm) [2] images. By performing diffusion imaging using different b values, it is possible to calculate the apparent diffusion coefficient (ADC, measured in μm/s). Areas of restricted diffusion show low ADC values and ADC values are inversely correlated with tumor cellularity. Therefore, reduction in ADC has been shown to have good correlation with response to cytotoxic therapy. Inflammatory tissue also shows high signal on diffusion images. Currently, diffusion imaging is mainly used for detection of abnormal cancerous tissue and involved lymph nodes. [25] Studies have also been conducted on the detection of active inflammation in IBD patients using diffusion imaging[26] [Figure 8].
Figure 8: A patient with rectal cancer. Diffusion-weighted MRI image shows high signal in the cancer tissue (arrow) and involved lymph node in the mesorectum (short arrow)

Click here to view


Perfusion imaging: Perfusion CT is a technique that integrates anatomic detail with assessment of vascular physiology. Analysis of tumor enhancement, tumor blood flow, blood volume, mean transit time, and permeability-surface area product are possible. Perfusion CT is a reflection of angiogenesis in tumors, and therefore its main use is in the assessment of colorectal tumors and their response to treatment. [27]

 
   References Top

1.Balthazar EJ, Herlinger H, Maglinte D, Birnbaum BA. Clinical Imaging of the Small Intestine. 2 nd ed. Germany: Springer; 2001.   Back to cited text no. 1
    
2.Maglinte DD, Kelvin FM, O'Connor K, Lappas JC, Chernish SM. Current status of small bowel radiography. Abdom Imaging 1996;21:247-57.   Back to cited text no. 2
[PUBMED]  [FULLTEXT]  
3.Maglinte DDT. Small bowel imaging: A rapidly changing field and a challenge to radiology. Eur Radiol 2006;16:967-71.   Back to cited text no. 3
    
4.Maglinte D, Sandrasegaran K, Tann M. Advances in alimentary tract imaging. World J Gastroenterol 2006;12:3139-45.   Back to cited text no. 4
    
5.Maglinte D, Sandrasegaran K, Chiorean M, Dewitt J, McHenry L, Lappas J. Radiologic investigations complement and add diagnostic information to capsule endoscopy of small-bowel diseases. AJR Am J Roentgenol 2007;189:306-12.   Back to cited text no. 5
    
6.Maglinte D, Sandrasegaran K, Lappas J, Chiorean M. CT Enteroclysis. Radiology 2007;245:661-71.   Back to cited text no. 6
    
7.Maglinte D, Chernish S, Kelvin F, O'Connor K, Hage J. Crohn disease of the small intestine: Accuracy and relevance of enteroclysis. Radiology 1992;184:541-5.   Back to cited text no. 7
    
8.Maglinte DD, Kohli MD, Romano S, Lappas JC. Air (CO2) double-contrast barium enteroclysis. Radiology 2009;252:633-41.   Back to cited text no. 8
[PUBMED]  [FULLTEXT]  
9.Rajesh A, Sandrasegaran K, Jennings SG, Maglinte DD, McHenry L, Lappas JC, et al. Comparison of capsule endoscopy with enteroclysis in the investigation of small bowel disease. Abdom Imaging 2009;34:459-66.   Back to cited text no. 9
[PUBMED]  [FULLTEXT]  
10.Sinha R, Murphy P, Hawker P, Sanders S, Rajesh A, Verma R. Role of MRI in Crohn's disease. Clin Radiol 2009;64:341-52.  Back to cited text no. 10
[PUBMED]  [FULLTEXT]  
11.Lauenstein T, Schneemann H, Vogt F, Herborn C, Ruhm S, Debatin J. Optimization of oral contrast agents for MR imaging of the small bowel. Radiology 2003;228:279-83.  Back to cited text no. 11
    
12.Ramachandran I, Sinha R, Rajesh A, Verma R, Maglinte D. Multidetector row CT of small bowel tumours. Clin Radiol 2007;62:607-14.   Back to cited text no. 12
    
13.Sinha R, Verma R. Multidetector row computed tomography in bowel obstruction, Part 1: Small bowel obstruction. Clin Radiol 2005;60:1058-67.   Back to cited text no. 13
[PUBMED]  [FULLTEXT]  
14.Pickhardt PJ, Hassan C, Halligan S, Marmo R. Colorectal cancer: CT colonography and colonoscopy for detection-systematic review and meta-analysis. Radiology 2011;259:393-405.   Back to cited text no. 14
[PUBMED]  [FULLTEXT]  
15.Sinha R. CT colonography: A practical guide. Indian J Radiol Imaging 2006;16:537-41.  Back to cited text no. 15
  Medknow Journal  
16.Maccioni F. Current status of gastrointestinal MRI. Abdom Imaging 2002;27:358-60.   Back to cited text no. 16
[PUBMED]  [FULLTEXT]  
17.Sinha R, Rajiah P, Murphy P, Hawker P, Sanders S. Utility of High-resolution MR imaging in demonstrating transmural pathologic changes in crohn disease. Radiographics 2009;29:1847-67.   Back to cited text no. 17
[PUBMED]  [FULLTEXT]  
18.Sinha R, Nwokolo C, Murphy PD. Magnetic resonance imaging in Crohn's disease. BMJ 2008;336:273-6.   Back to cited text no. 18
[PUBMED]  [FULLTEXT]  
19.Puylaert JB. Ultrasound of acute GI tract conditions. Eur Radiol 2001;11:1867-77.   Back to cited text no. 19
[PUBMED]  [FULLTEXT]  
20.Maconi G, Radice E, Bareggi E, Porro GB. Hydrosonography of the Gastrointestinal Tract. AJR Am J Roentgenol 2009;193:700-8.   Back to cited text no. 20
[PUBMED]  [FULLTEXT]  
21.Migaleddu V, Quaia E, Scano D, Virgilio G. Inflammatory activity in Crohn disease: Ultrasound findings. Abdom Imaging 2008;33:589-97.   Back to cited text no. 21
[PUBMED]  [FULLTEXT]  
22.Veit-Haibach P, Kuehle CA, Beyer T, Stergar H, Kuehl H, Schmidt J, et al. Diagnostic accuracy of colorectal cancer staging with whole-body PET/CT colonography. JAMA J Am Med Assoc 2006;296:2590-600.   Back to cited text no. 22
    
23.Vogel WV, Wiering B, Corstens FH, Ruers TJ, Oyen WJ. Colorectal cancer: the role of PET/CT in recurrence. Cancer Imaging 2005;5:S143-9.   Back to cited text no. 23
[PUBMED]  [FULLTEXT]  
24.Vlachou P, Sinha R, Verma R. Recurrent rectal tumour: Localization using CT-guided percutaneous "breast coil" placement prior to surgery. Br J Radiol 2007;80:241-2.   Back to cited text no. 24
    
25.Koh D, Collins D. Diffusion-weighted MRI in the body: Applications and challenges in oncology. AJR Am J Roentgenol 2007;188:1622-35.  Back to cited text no. 25
    
26.Oto A, Zhu F, Kulkarni K, Karczmar GS, Turner JR, Rubin D. Evaluation of diffusion-weighted MR imaging for detection of bowel inflammation in patients with Crohn disease. Acad Radiol 2009;16:597-603.   Back to cited text no. 26
[PUBMED]  [FULLTEXT]  
27.Figueiras RG, Goh V, Padhani AR, Naveira AB, Caamaño AG, Martin CV. The role of functional imaging in colorectal cancer. AJR Am J Roentgenol 2010;195:54-66.  Back to cited text no. 27
    

Top
Correspondence Address:
Rakesh Sinha
Department of Clinical Radiology, South Warwickshire NHS Foundation Trust and Warwick Medical School, Lakin Road, Warwick CV345BW
United Kingdom
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/0971-3026.85363

Rights and Permissions


    Figures

  [Figure 1], [Figure 2], [Figure 3], [Figure 4], [Figure 5], [Figure 6], [Figure 7], [Figure 8]

This article has been cited by
1 Diffusion-weighted MR imaging of the gastrointestinal tract: Technique, indications, and imaging findings
Sinha, R. and Rajiah, P. and Ramachandran, I. and Sanders, S. and Murphy, P.D.
Radiographics. 2013; 33(3): 655-676
[Pubmed]
2 Diffusion-weighted MR Imaging of the Gastrointestinal Tract: Technique, Indications, and Imaging Findings
Rakesh Sinha,Prabhakar Rajiah,Iswaran Ramachandran,Scott Sanders,Paul D. Murphy
RadioGraphics. 2013; 33(3): 655
[Pubmed] | [DOI]
3 Errors in the Radiological Evaluation of the Alimentary Tract: Part II
Reginelli, A. and Mandato, Y. and Solazzo, A. and Berritto, D. and Iacobellis, F. and Grassi, R.
Seminars in Ultrasound, CT and MRI. 2012; 33(4): 308-317
[Pubmed]
4 CT enteroclysis and CT enterography -new approaches to assessing pathology of the small intestine [Enterokliza i enterografia tomografii komputerowej - nowe metody oceny patologii jelita cienkiego]
Lebda-Wyborny, T. and Barczyk, A. and Pilch-Kowalczyk, J. and Korzekwa, M. and Sojka, D. and Knap, D. and Baron, J. and Palasz, A.
Chirurgia Polska. 2012; 14(1-2): 69-80
[Pubmed]
5 Errors in the Radiological Evaluation of the Alimentary Tract: Part II
Alfonso Reginelli,Ylenia Mandato,Antonio Solazzo,Daniela Berritto,Francesca Iacobellis,Roberto Grassi
Seminars in Ultrasound, CT and MRI. 2012; 33(4): 308
[Pubmed] | [DOI]



 

Top
 
 
  Search
 
   Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
    Email Alert *
    Add to My List *
* Registration required (free)  


    Abstract
   Introduction
    Current Role of ...
   CT Scan and MRI
   Functional Imaging
    References
    Article Figures

 Article Access Statistics
    Viewed8775    
    Printed162    
    Emailed5    
    PDF Downloaded997    
    Comments [Add]    
    Cited by others 5    